Monoprice
Monoprice 130662 Cat6A Bulk Ethernet Cable 1000ft Blue
★★★★★
A 1000-foot spool of shielded Cat6A bulk cable lets you build a purpose-cut, 10-gigabit infrastructure without paying for patch cable waste or compromising on shielding.
$321.80*$338.06Save 4%
View on Amazon
✓ In Stock on Amazon.com
*Price sourced from Amazon.com. Last updated:Jul 16, 2026.Price and availability are subject to change.
Affiliate Disclosure: Studio Supplies may earn a commission from qualifying purchases made through links on this page, at no additional cost to you. This helps support our editorial team.
Notice a mistake? Let Us Know
Overview
Key Features
Buy with Confidence: With Monoprice's Lifetime Warranty on all Cables, you can rest assured we stand behind our products and our customers.
CMR Riser rated.
F/UTP shielded.
1000ft spool.
Great for 10G environments.
Specifications
Cable Type
Cat6A Bulk Ethernet
Length
1000 ft
Color
Blue
Shielding
F/UTP Shielded
Rating
CMR Riser
Application
10G Environments
Pros & Cons
👍 Pros
- The 650MHz bandwidth exceeds the 500MHz minimum for 10GBASE-T, providing signal headroom that helps maintain link stability across full 100-meter runs.
- F/UTP foil shielding reduces alien crosstalk in dense cable environments — critical for server rooms and production facilities where dozens of cables share conduit.
- Bare copper conductors meet TIA-568 standards and deliver reliable PoE power delivery across long runs without the resistance issues of copper-clad aluminum alternatives.
- A 1000-foot spool allows complete infrastructure runs to be cut to exact lengths, eliminating patch cable slack and reducing cable management complexity.
- CMR riser rating satisfies building code requirements for vertical cable runs between floors without needing a separate fire-rated cable specification.
👎 Cons
- F/UTP cable requires shielded termination hardware — jacks, keystones, and patch panels — to realize the full crosstalk rejection benefit, adding cost and installation complexity versus unshielded runs.
- The shielding requires proper grounding at termination points; an improperly grounded shield can act as an antenna and introduce noise rather than reject it.
- CMR rating does not satisfy plenum (CMP) requirements — in air-handling spaces where building codes mandate plenum cable, this spool cannot be used.
- 1000 feet is the only available quantity — for small installations requiring less cable, purchasing a full spool means significant unused material.
Frequently Asked Questions
What does F/UTP shielding actually do for a 10G network, and when do I need it?
F/UTP means a foil shield wraps the entire cable bundle — this significantly reduces alien crosstalk from adjacent cables in conduit or cable trays, which becomes a real performance issue at 10G speeds over Cat6A. In clean residential or small office runs with minimal EMI sources, unshielded Cat6A can work, but F/UTP is the correct choice for server rooms, industrial environments, or anywhere cables run parallel in tight bundles over distance.
What maximum run length supports 10G on this cable?
Cat6A is specified for 10GBASE-T at up to 100 meters (328 feet) per channel — well within the 100m Ethernet limit. At that distance and cable category, you're comfortably running 10G without needing to step up to fiber. For shorter runs, the 650MHz bandwidth provides significant headroom above the 500MHz minimum required for 10GBASE-T.
Is this cable CMR (riser) rated, and what does that mean for my installation?
Yes, this cable is CMR (Communications Multipurpose Cable, Riser) rated, meaning it meets fire resistance requirements for vertical runs between floors in a building — it's designed to limit flame spread in a riser shaft. It is not plenum-rated (CMP), so if your local code requires plenum cable in air-handling spaces, you'll need a different product.
Do I need shielded keystone jacks and patch panels to terminate this cable properly?
Yes — F/UTP cable should be terminated with shielded (FTP/STP-compatible) jacks and panels to complete the shielding continuity. Terminating shielded cable into unshielded keystones partially defeats the crosstalk rejection benefit. The cable also requires proper grounding at patch panel termination points for the shield to function correctly.
What wire gauge is this cable, and does bare copper matter for performance?
Cat6A bulk cable uses 23 AWG bare copper conductors — bare copper (as opposed to copper-clad aluminum, or CCA) is the specification-compliant choice for Cat6A and delivers lower DC resistance per foot, which matters for both signal integrity and PoE applications. CCA cable fails TIA-568 standards and can cause PoE power delivery problems on longer runs.