Monoprice 140041 3ft C14 to C19 Power Cord

3.0 (2 reviews)

14 AWG, 15A, C14-to-C19 rated for data center PDU connections where most power cords fall short on gauge and connector spec.

$19.55*
In Stock on Amazon.com
View on Amazon

*Price sourced from Amazon.com. Last updated:Jul 14, 2026.Price and availability are subject to change.

Affiliate Disclosure: Studio Supplies may earn a commission from qualifying purchases made through links on this page, at no additional cost to you. This helps support our editorial team.

Notice a mistake? Let Us Know

Overview

The Monoprice 140041 is a 3-foot C14-to-C19 power cord built to the specification that data center and network rack installations actually require: 14 AWG conductors, a 15A current rating, and a 100–250V operating range with an SJT thermoplastic jacket. The C14-to-C19 connector combination is not arbitrary — it is the IEC 60320 pairing specifically used between rack-mounted Cisco and Juniper network equipment and the power distribution units (PDUs) that feed them. Running this connection on a thinner, lower-rated cord is a code violation and a thermal risk under sustained load; 14 AWG eliminates that concern. The fully molded connector bodies provide mechanical integrity at both ends, and the color-coded jacket enables standard color-coding practices in high-density cable environments.

This cord is built for network equipment rooms, data centers, and structured rack installations where power delivery reliability is not optional. The 3-foot length is intentional — within-rack reach from a rack-mounted PDU to the power inlet on a 1U or 2U switch or router. System integrators and data center technicians who stock spares or build out new rack deployments will find the Monoprice 140041 a cost-effective specification-grade cord. It is not a general-purpose extension cable — it is a purpose-built link in a defined power chain, and it performs that role with the conductor gauge and connector standard the application demands.

Key Features

Heavy duty 14 AWG power cord is fully molded for PDU or UPS in data center.

Recommended for powering computers, monitors, and other essential peripherals.

Extend the length of an existing power cord for more flexibility.

Colored cord is designed for easy identification in a high density data environment.

IEC 60320 C14 to IEC 60320 C19 power cords are commonly used between Cisco or Juniper Networks rack mounted equipment and the PDU in a data cabinet.

Specifications

Cable Length
3 feet
Connector Type 1
IEC C14
Connector Type 2
IEC C19
Wire Gauge
14 AWG
Construction
Fully molded
Recommended Use
PDU or UPS in data center, powering computers, monitors, peripherals
Specific Applications
Cisco or Juniper Networks rack mounted equipment to PDU

Pros & Cons

👍 Pros

  • 14AWG conductors are correctly sized for the 15A continuous load rating, maintaining safe operating temperature under sustained server and network equipment power draw.
  • 14 AWG conductor handles the full 15A rating continuously without resistive heat buildup — the correct gauge for sustained loads from rack-mounted networking and server equipment.
  • C14-to-C19 connector pairing matches the exact interface standard used between Cisco, Juniper, and similar rack gear and their corresponding PDUs, eliminating adapter workarounds.
  • The IEC 60320 C14-to-C19 connector pair is the industry-standard combination for rack equipment to PDU connections in Cisco, Juniper, and APC infrastructure deployments.
  • 100–250V universal voltage range makes the cord usable in both North American and international data center power environments without substitution.
  • 100–250V voltage rating spans both North American and international AC standards, making the cable suitable for multi-region deployments without separate SKUs.
  • Fully molded connector construction creates a sealed, mechanically robust junction that resists moisture ingress and physical stress during cable pull and rack reconfiguration.
  • The fully molded SJT jacket construction resists the flex fatigue that accumulates from repeated cable routing and re-routing during rack maintenance cycles.
  • Colored cord construction enables circuit-level color coding in high-density environments, reducing human error during power maintenance operations.
  • Color-coded jacket enables rapid visual identification in high-density cable environments — a standard data center cable management practice that reduces operational errors.

👎 Cons

  • The 3-foot length is purpose-built for same-rack installations — cross-rack or overhead PDU deployments require longer variants, and ordering the wrong length is a common procurement mistake.
  • At 3 feet, this cable is designed for within-rack reach — it does not span between adjacent racks or equipment positioned more than a short distance from the PDU.
  • The SJT jacket, while flexible and appropriate for indoor use, is not rated for plenum or riser applications — installations in air-handling spaces or vertical cable runs between floors require a separately rated cord.
  • The C19 connector format is not backward-compatible with C13 outlets — this cord cannot be used as a substitute where C13 PDU outlets are installed.
  • SJT jacket rating is appropriate for data center indoor use but is not rated for outdoor, wet location, or industrial floor environments.
  • The C19 female end is a locking-style connector standard on the equipment side but does not include a positive retention latch — in high-vibration environments, mechanical retention relies solely on connector friction.
  • Monoprice does not publish UL certification details prominently for this SKU — buyers in environments with strict compliance requirements should verify listing before specifying.
  • The cord is black in this listing — color-coded variants for specific circuit identification require sourcing different SKUs, which adds procurement complexity in large deployments.
  • No locking connector mechanism — C14 and C19 connections rely on friction retention, which means accidental disconnection is possible in racks subject to vibration or frequent cable movement.
  • At 3 feet, the cord provides limited slack for cable dressing — racks with PDUs mounted at non-standard positions may find the length restrictive for neat management.

Frequently Asked Questions

C14 inlets are standard on rack-mounted equipment power supplies, KVM switches, and mid-range APC/Eaton UPS units. C19 outlets are found on high-capacity PDUs and UPS systems — particularly those from Cisco, Juniper, and APC. If your equipment has a C14 power inlet and your PDU has C19 outlets, this is the correct cord.
C14 is a male inlet rated for 10A in IEC standard (15A in North American practice), commonly found on power supplies and rack PDU tails. C19 is a heavier-duty female connector rated for 16A/20A, used on high-draw rack equipment and PDUs. This C14-to-C19 configuration is the standard connection between Cisco and Juniper rack-mounted gear and a PDU — it is a load-bearing link in the data center power chain.
Lower AWG numbers mean thicker wire and lower resistance. At 14 AWG, this cord handles 15A continuously without resistive heating that would be present in a thinner 18 AWG cable under the same load. For data center equipment drawing sustained current, 14 AWG is the appropriate gauge.
The 140041 is rated at 15A and 100–250V with a 14AWG SJT jacket. At 15A/250V, it supports up to 3,750W of load — sufficient for most rack-mounted servers, switches, and storage arrays at standard data center power densities.
Wire gauge determines how much current the cord can carry safely without excessive resistance heating. 14AWG is rated for 15A continuous load, which is the correct gauge for C14-to-C19 cords serving rack equipment at standard PDU amperage. Thinner gauges (16AWG or 18AWG) are not appropriate for C19 PDU connections under sustained server load.
Yes, provided the source cord terminates in a C14 male connector. The Monoprice 140041 adds 3 feet of extension between a C14 source and a C19 inlet — useful for repositioning equipment within a rack without full cable replacement.
SJT (Service Junior Thermoplastic) indicates a flexible, thermoplastic outer jacket rated for general-purpose use. It is appropriate for indoor data center environments, PDU connections, and rack cable management — not for outdoor or wet location use.
Three feet is the standard length for within-rack C14-to-C19 connections where the equipment and the PDU are both mounted in the same rack. For cross-rack or overhead PDU installations, 6-foot or 10-foot variants are more appropriate. Measure your rack's PDU position relative to equipment before ordering.
Yes — colored power cords are a standard data center cable management practice. Color-coding by circuit, PDU branch, or power feed allows technicians to identify power sources at a glance in dense cabinet environments, reducing the risk of accidentally disconnecting the wrong circuit during maintenance.
Functional. In high-density data centers where dozens of identical-looking cables run to a PDU, color coding is a standard cable management practice. Color identification reduces the risk of pulling the wrong cord during hot-swap or emergency power operations.