Monoprice 140041 3ft C14 to C19 Power Cord
14 AWG, 15A, C14-to-C19 rated for data center PDU connections where most power cords fall short on gauge and connector spec.
*Price sourced from Amazon.com. Last updated:Jul 14, 2026.Price and availability are subject to change.
Notice a mistake? Let Us Know
Overview
Key Features
Heavy duty 14 AWG power cord is fully molded for PDU or UPS in data center.
Recommended for powering computers, monitors, and other essential peripherals.
Extend the length of an existing power cord for more flexibility.
Colored cord is designed for easy identification in a high density data environment.
IEC 60320 C14 to IEC 60320 C19 power cords are commonly used between Cisco or Juniper Networks rack mounted equipment and the PDU in a data cabinet.
Specifications
Pros & Cons
👍 Pros
- 14AWG conductors are correctly sized for the 15A continuous load rating, maintaining safe operating temperature under sustained server and network equipment power draw.
- 14 AWG conductor handles the full 15A rating continuously without resistive heat buildup — the correct gauge for sustained loads from rack-mounted networking and server equipment.
- C14-to-C19 connector pairing matches the exact interface standard used between Cisco, Juniper, and similar rack gear and their corresponding PDUs, eliminating adapter workarounds.
- The IEC 60320 C14-to-C19 connector pair is the industry-standard combination for rack equipment to PDU connections in Cisco, Juniper, and APC infrastructure deployments.
- 100–250V universal voltage range makes the cord usable in both North American and international data center power environments without substitution.
- 100–250V voltage rating spans both North American and international AC standards, making the cable suitable for multi-region deployments without separate SKUs.
- Fully molded connector construction creates a sealed, mechanically robust junction that resists moisture ingress and physical stress during cable pull and rack reconfiguration.
- The fully molded SJT jacket construction resists the flex fatigue that accumulates from repeated cable routing and re-routing during rack maintenance cycles.
- Colored cord construction enables circuit-level color coding in high-density environments, reducing human error during power maintenance operations.
- Color-coded jacket enables rapid visual identification in high-density cable environments — a standard data center cable management practice that reduces operational errors.
👎 Cons
- The 3-foot length is purpose-built for same-rack installations — cross-rack or overhead PDU deployments require longer variants, and ordering the wrong length is a common procurement mistake.
- At 3 feet, this cable is designed for within-rack reach — it does not span between adjacent racks or equipment positioned more than a short distance from the PDU.
- The SJT jacket, while flexible and appropriate for indoor use, is not rated for plenum or riser applications — installations in air-handling spaces or vertical cable runs between floors require a separately rated cord.
- The C19 connector format is not backward-compatible with C13 outlets — this cord cannot be used as a substitute where C13 PDU outlets are installed.
- SJT jacket rating is appropriate for data center indoor use but is not rated for outdoor, wet location, or industrial floor environments.
- The C19 female end is a locking-style connector standard on the equipment side but does not include a positive retention latch — in high-vibration environments, mechanical retention relies solely on connector friction.
- Monoprice does not publish UL certification details prominently for this SKU — buyers in environments with strict compliance requirements should verify listing before specifying.
- The cord is black in this listing — color-coded variants for specific circuit identification require sourcing different SKUs, which adds procurement complexity in large deployments.
- No locking connector mechanism — C14 and C19 connections rely on friction retention, which means accidental disconnection is possible in racks subject to vibration or frequent cable movement.
- At 3 feet, the cord provides limited slack for cable dressing — racks with PDUs mounted at non-standard positions may find the length restrictive for neat management.